Aparatura de masura si control - peste 1.000 de produse de la cele mai renumite marci europene
CERTIFICARI:  ISO 9001 / 2008   |    INFO LINE:  021.444.14.35  021.777.59.53   |    Sunati-ma voi!
REGULATOARE, CONTACTOARE, TEHNICA DE SISTEM



MASURARE WIRELESS A TEMPERATURII

Wireless probe RTD temperature probe with wireless transmission of the measured values (90.2930)
* For operating temperatures from -30 ... +260°C
* For mobile or stationary temperature measurement
* Open air range 300m (1000 feet)
* No wiring work due to state-of-the-art wireless technology
* Fail-safe transmission through telegram frame coding

Receiver for RTD temperature probes with wireless transmission of the measured values (90.2931)
* For operating temperatures from -30 ... +260°C
* For mobile or stationary temperature measurement
* Open air range 300m (1000 feet)
* No wiring work due to state-of-the-art wireless technology
* Fail-safe transmission through telegram frame coding



COMANDA PROCESELOR SI APARATE CU PROGRAM

Process controllers for the meat processing industry (70.0101)
* Two screen layout templates (masks) for automatic operation and one for the basic status, all freely editable
* 5" color display, 12mm LED displays for process values
* Plug & Play memory, to back up configuration data, transfer programs from one instrument to another, and to read in instrument software
* Configuration and parameter levels in English, German, French
* Math and logic functions
* Teleservice via modem
* Setup program
* Program editor


Controller for boilers, cooking chambers and baking installations, bezel size 96 x 96mm (70.0201)
* Compact dimensions 96 x 96mm
* Easy operation
* Integral real-time clock for starting at any specific time
* Delta cooking and F-value cooking
* 2 limit comparators
* Combination alarm Analogue inputs Pt 100 in 3-wire circuit, thermocouple Fe-Con J, 0(4) - 20mA or 0 - 10V
* 1 analogue output
* Logic outputs in the form of relays with 2 n. o. (make) and 2 changeover contacts
* LON interface
* PID single-setpoint or double-setpoint controller
* Display of operating status
* Interval spray
* Protection IP65 at the front


Channel indicator and monitoring unit for mTRON analogue input modules (70.0202)
* Compact dimensions 96 x 96 cm
* Simple operation
* Integral real-time clock
* Digital outputs in the form of relays with up to 2 normally open and 2 changeover contacts
* LON interface
* Simple installation
* IP65 front protection




SOFTWARE PENTRU AUTOMATIZARE

Plant visualization software with batchrelated data report and evaluation for networks (70.0753)
* Network functionality: The visualization and report generation can be freely defined for each station
* Easy creation of applications: Quick and simple creation of the applications by using predefined graphic objects for JUMO instruments
* Data recording: Batch-related report generation and data recording for a process; Batch reporting with a search function for time, date, batch number, product name or program number; Data recording to hard disk
* Display: Simultaneous group and trend displays; System-specific alarm and event lists
*Real-time operation: Real-time visualization of and switching between group displays, trend displays, alarm or event lists; with specifically set-up variables, editable (e.g.setpoints, via system diagrams); The sampling rate per interface and per connected instrument is from 0.7 to 2 seconds




TERMOSTATE ELECTRONICE/MICROSTATE

Electronic Refrigeration Controller, bezel size 76mm x 36mm (70.1061)
* Choice of “electrical” or “hot gas” defrosting process
* 16A relay for cooling unit and 8A relay for defrosting and fan functions
* 2 analog inputs for RTDs, KTY1X-6 or KTY2X-6 in 2-wire circuit
* Customized linearization is programmable through the setup program
* Operating hours counter with integrated service counter
* Alarm generation via relay or buzzer
* Available with real-time clock, data logger, and RS485 interface
* The data logger records the measurement inputs and switching states of all relays. This makes it possible to implement HACCP monitoring of the cold chain
* Up to 8 parameters can be enabled individually for the operating level
* The parameter level is protected by a code, thus preventing any unauthorized access to the instrument data
* Meets the requirements as per EN 12830 and EN 13485
* Setup program for instrument configuration and evaluation of the data logger


Electronic microstat, bezel size 76 x 36mm (70.1060)
* Integrated defrosting function
* Heating or cooling is configurable
* Limit monitoring
* Available for resistance thermometer, thermocouple, standard current or voltage signals, according to choice
* Choice of a 10A relay or two 5 A relays
* Adjustable switching hysteresis
* Time-delayed switch-on after power-on is selectable, e. g. for staggered starting of several equipment units
* Operating hours counter
* Symbols for operating modes, °C, °F, hours, minutes and seconds in display
* Parameter level protected by code
* Setup program for configuration and archiving via PC
* Customized linearization via tabular function in the setup program
* UL approval


Digital thermostat with LC display for mounting on a 35mm DIN rail (70.1050)
* Heating or cooling is configurable
* Limit monitoring
* Available for resistance thermometer, thermocouple, standard current or voltage signals, according to choice
* Choice of a 10A relay or two 5 A relays
* Adjustable switching hysteresis
* Time-delayed switch-on after power-on is selectable, e. g. for staggered starting of several equipment units
* Operating hours counter
* Symbols for operating modes, °C, °F, hours, minutes and seconds in display
* Parameter level protected by code
* Setup program for configuration and archiving via PC
* Customized linearization via tabular function in the setup program
* UL approval




SUPRAVEGHETOARE / LIMITATOARE DE TEMPERATURA

Temperature monitor/limiter and safety temperature monitor/limiter for mounting on DIN rail (70.1130)
* Input for resistance thermometer or double thermocouple
* O- and S-function for rising and falling temperatures
* Connection for an external reset pushbutton (TB, STB)
* Approved to DIN 3440
* GL approval


Temperature limiter, temperature monitor according DIN EN 14 597 (70.1160)
* Setup program for configuration and archive data backup
* Clear, easy-to-read alphanumerical display
* Digital input filter with adjustable ilter time constant
* Adjustable as absolute value or relative to limit value
* Wide supply voltage range 110 — 240V AC +10% /-15%
* Configurable as TB or TW
* 17 linearizations can be set
* Internal and external locking options
* Input 2 x




AFISAJE DIGITALE

Handheld Thermometer with data logger (70.2540)
* Measurement input for Pt100, NiCr-Ni K, Fe-Con J and Cu-Con T
* Available with DKD calibration certificate
* Data logger for 9999 measurements
* Simple readout via USB and evaluation of data from a PC (TDA-3000 only)
* Limit monitoring
* Peak/bottom value acquisition
* Battery AA, Mignon LR6, with a long service life


Digital microprocessor indicator with 1 logic input and 1 switching output, bezel size 48 x 24mm,JUMO di 08 Digital microprocessor indicator with 1 logic input and 2 switching outputs, bezel size 96 x 48mm (70.1530/95.1530
* Structured operating and programming layout
* Customer-specific linearization correction
* 2 limit comparators for limit monitoring
* Digital input filter with programmable filter time constant
* Time-delayed switching, programmable per relay
* Switch-on delay after power-on is programmable


Portable digital microprocessor thermometers with interchangeable probes (70.2510/95.2510)
TDAt-55 and TDAw-55 are compact electronic thermometers with a very fast response. They are used with precision thermocouples or resistance thermometers to measure temperatures on surfaces, in liquids, in melts, gases and soft or loose materials


Indicating instrument, programmable via PC Setup with voltage output 24V DC / 45mA, bezel size 96 x 48mm (70.1520/95.1520)
* Configuration from PC through setup program
* Electrically isolated measurement input (setup is not isolated from the measurement input)
* Many different inputs possible: resistance thermometer in 2-/3-/4-wire circuit, thermocouple, resistance transmitter, standard signals, potentiometer in 2-/3-/4-wire circuit
* Internal cold junction
* Customised linearisation
* Offset correction
* Input filter for interference suppression
* 24 V supply for 2-wire transmitter


Digital temperature indicator with 10A changeover relay, bezel size 76 x 36mm, for connection to thermocouples; standard signals; Pt100, Pt1000 and KTY2X-6 in 2-wire circuit (70.1540/95.1540)
* Limit monitoring
* Available for resistance thermometer, thermocouple, standard current or voltage signals, according to choice
* 10A relay (changeover contact)
* Adjustable switching hysteresis
* Programmable switch-on delay after power-on
* Configurable alarm suppression
* Symbols in display for temperature unit, minutes and seconds
* Parameter level protected by code
* Setup program for configuration and archiving via PC
* Customized linearization via tabular function in the setup program
* UL approval




REGULATOARE DE PROCES COMPACTE

Compact laboratory controller in a plastic benchtop case (70.0702)
* Structured operating and programming scheme
* Self-optimisation
* Ramp function
* Programme function with four profile segments
* Digital input filter with programmable filter time constant
* RS485 serial interface
* Key and level inhibit
* 2 setpoints with setpoint switching
* 2 parameter sets with parameter set switching


Compact microprocessor controllers, bezel size 96 x 96(48)mm, 48 x 48mm and 48 x 24mm (70.2040)
* Structured operating and programming layout
* Self-optimisation
* Ramp function
* Timer function
* Digital input filter with programmable filter time constant
* 1 limit comparator
* Limit switch


Microprocessor controller with a 2-line LC display for mounting on a 35mm DIN rail (70.2060)
* Freely configurable measurement input
* Ramp function
* Timer function
* Self-optimization
* Clear, easy-to-read alphanumeric display
* Sampling time 210 msec
* Setup program for configuration and archiving from a PC


Compact microprocessor controller, bezel size 96 x 96mm for the food industry (70.2050)
* Simple operation
* Timer function (Type 702050/1 . . only)
* Digital input filter with programmable filter time constant
* Limit comparator (Types 702050/1 . . and 702050/2 . . only)
* Easy-to-clean membrane keypad
* Suitable for ambient temperatures up to 60°C
* Three relays with 5A contact rating at 230V (Type 702050/1 . . only)
* Trilingual setup program (German, English, French)
* UL approval (in preparation)


Compact Controller for the plastics industry (70.3046)
* Control loop monitoring
* Output level monitorin
* Hot-channel warm-up ramp
* Heater current monitoring
* Modbus master function
* Boost function
* Four programmable setpoints, two parameter sets
* Math and logic module
* Two autotuning procedures
* Fast, user-friendly configuration through the setup program with program editor
* RS422/485 interface
* PROFIBUS-DP interface
* Current interface 0/20mA (as per Euromap


Compact microprocessor controller, bezel size 48 x 48mm (70.3011)
* Structured operating and programming layout
* Self-optimisation
* Ramp function
* Profile program function with four profile segments
* External setpoint input
* Digital input filter with programmable time constant
* Serial interface RS485
* 2 limit comparators
* 5 outputs with freely assigned functions
* Process value output
* Key and level inhibits
* 2 setpoints with setpoint selection
* 2 parameter sets with parameter set switching
* UL and FM approval


Compact controller with program function, bezel size 48mm x 48mm, 48mm x 96mm, 96mm x 48mm and 96mm x 96mm (70.3041)
* Max. two programmable analog inputs
* Four programmable setpoints, two parameter sets
* Program function with 8 segments, or ramp function
* Math and logic module
* 4 limit comparators
* Two timer functions
* Two self-optimization procedures
* Fast, user-friendly configuration through the setup program with program editor
* RS422/485 interface
* Profibus-DP interface
* cUL/UL approval applied for


Compact microprocessor controllers, bezel size 96 x 96(48)mm (70.3030)
* Structured operating and programming scheme
* New self-optimisation
* Fuzzy module
* Ramp function
* Start-up ramp for hot channel method (not with extra Code 050)
* Output indication on modulating controller
* Heater current monitoring
* External setpoint input
* Digital input filter with programmable time constant
* Serial interface
* 2 limit comparators
* 5 outputs with freely assigned functions
* Parameter set switching
* UL approval


Universal process controllers, bezel size 96 x 96(48)mm (70.3570)
* Switchable displays
* Text or bar graph display
* 8 limit comparators
* 4 setpoints
* 2 parameter sets
* Maths and logic module
* Ramp and profile program function
* Setup program with JUMO start-up software
* Approved to DIN 3440 (for Type 703570)
* UL approval
* GL approval


Universal profile controllers/generators (70.3580)
* Switchable displays
* Text or bar graph display
* 8 limit comparators
* 2 parameter sets
* Maths and logic module
* 8 operating contacts
* Real-time clock
* Setup program with program editor and JUMO start-up software for Windows® 95/98/NT4.0/2000/XP


Automation system, Controller module (70.4010)
* Maths functions: Difference, humidity, ratio, square root, square, minimum, maximum, absolute value, sum, product, mean value
* Ramp function: Setpoint ramp for a time-defined approach of the process to the setpoint
* Limit comparator: Comparator and window functions, direct or reversed
* Switching setpoint/parameter set: Facility for switching between 4 setpoints and 2 controller parameter sets through logic inputs and network variables
* Range monitor: The analogue inputs are monitored against defined limit values
* Cascade output: Conversion of the setpoint input for an external slave controller
* Setup interface: For configuration and setting of parameters, the module is linked to a PC via a PC interface
* Plug & Play function: Problem-free replacement of modules without re-configuration


Automation system, Analog input module (70.4020)
* Math functions: Difference, humidity, ratio, square root, square, minimum, maximum, absolute value, sum, product, mean value
* Limit comparator: Comparator and window functions, direct or reversed, with switch-on and switch-off delay, also latching and gate circuit
* Customized linearization: Linearization function with up to 21 calibration points
* Range monitoring: The analog inputs are monitored against definable limit values
* Setup interface: For configuration and parameter setting the module is linked to a PC via a PC interface
* Plug-&-Play-Function: Problem-free replacement of modules without re-configuration


Automation system, Logic module (70.4030)
* 8 logic inputs
* 6 switching outputs
* Real-time clock
* Network inputs: 8 logic, 4 long, 8 real
* Network outputs: 8 logic, 4 long, 8 real combined alarm switching status of inputs/outputs date/time
* 2 hardware counters: for counting pulses and time measurements via the logic inputs
* Programming through "Structured text" to DIN 1131
* Function blocks to DIN 1131
* Debugger for program testing (via JUMO mTRON iTOOL)
* Setup interface: For configuration and parameter setting, the module is linked to a PC via a PC interface
* Plug & Play function: Problem-free replacement of modules without re-configuration


Automation system, Communication module (70.4040)
* Visualisation via MODbus
* Connection to PLC via MODbus
* Configuration and parameter setting via JUMO mTRON-iTOOL project design software
* Modem operation for configuration and setting parameters of a JUMO mTRON automation system over any distance
* Several communication modules can operate in a network
* Automatic dialling of a telephone number via modem on alarm in the LON network
* Integral RS232, RS422 or RS485 interface


Automation system, Project design software JUMO mTRON-iTOOL (70.4090)
* Project design: The modules are selected, links between them are defined through network variables and assigned to the modules in the system
* Download (upload): The data can be loaded into the system, either individually or for the entire project
* Modem: Download/upload via modem for remote servicing is available
* NV monitor: Any network variables can be monitored on-line
* Drag & Drop: Quick and intuitive working through Drag & Drop
* Off-line operation: A project can be edited without any connection to the network
* Project documentation: The entire project as well as each individual module (memo) can be documented


Automation system, Relay module (70.4015)
* Limit comparators: Comparator and window functions, direct or reversed, with switch-on and switch-off delay, also latching and gate circuit
* Pulse width modulation: PD controller converting the analogue control signals into switching pulses for operating contactors and solenoid valves
* Pulse frequency modulation: This function converts analogue control signals into switching pulses for operating dosing pumps, for example
* Actuator driver: Controller for operating actuating motors with position retransmission
* Setup interface: For configuration and setting of parameters the module is linked to a PC via a PC interface
* Plug & Play function: Problem-free replacement of modules without re-configuration


Automation system, Analogue output module (70.4025)
* Isolated outputs: The analogue output module has two isolated analogue outputs (current 0 - 20mA or 4 - 20mA / voltage 0 - 10V or 2 - 10V)
* Scaling: The analogue network inputs can be freely scaled using two parameters
* Limiting: The analogue outputs can be limited through two parameters
* Setup interface: For configuration and setting of parameters, the module is linked to a PC via a PC interface
* Plug & Play function: Problem-free replacement of modules without re-configuration


Automation system, Operating unit (70.4035)
* Operation and display of the entire JUMO mTRON automation system through process windows
* Configuration and parameter setting on all modules of a JUMO mTRON automation system
* Display of up to 16 process-operated alarms
* Setup interface: For configuration and parameter setting the module is linked to a PC via a PC interface
* Plug & Play function: Problem-free replacement of modules without re-configuration


Automation system, Controller operating unit (70.4045)
* Operation and display of up to 63 JUMO mTRON controller modules through process windows
* Configuration and parameter setting of the JUMO mTRON controller modules with clear user guidance
* Inhibit: Access to the controller parameters can be inhibited by logic inputs
* Alarms e.g. on sensor break or module failure
* Limit monitoring: up to 126 analogue inputs can be monitored for limits
* Plug & Play function: Problem-free replacement of modules without re-configuration




INREGISTRATOARE

Pen recorder with universal inputs, scale and text printing (70.6001/95.3530)
* Universal inputs
* Text printing
* Failure and fault analysis
* Compliance with official regulations
* Reports for users and customers
* Monitoring of processes
* Optimization of procedures


Pen recorder with univeral inputs, display and text printing (70.6021/95.3540)
* Universal inputs
* Text printing
* Failure and fault analysis
* Compliance with official regulations
* Reports for users and customers
* Monitoring of processes
* Optimization of procedures


Printing recorder with standard signal inputs, display and text printing (70.6031/95.4013)
* Printed text (limited)
* Event- and time-controlled chart speed
* Universal chart cassette


Pen recorder with standard signal inputs, scale and text printing (70.6011/95.3535)
* Failure and fault analysis
* Text printing
* Compliance with official regulations
* Reports for users and customers
* Monitoring of processes
* Optimization of procedures


Printing recorder with universal inputs, display and text printing (70.6030/95.4012)
* Limit monitoring
* Event traces
* Four open-collector outputs
* Peak value recording
* Extensive text printing
* Statistics (report) with minimum, maximum and mean values
* Event- and time-controlled chart speed
* Math and logic module (PC setup program is required)
* Universal chart cassette


Paperless recorder with CompactFlash card and life-cycle data management (70.6510)
* Measurement data presented numerically as vertical diagrams (with scaling, numerical display, or as a bar graph)
* Presentation of event traces such as “Binary inputs”
* On-site availability of measurements in the FLASH memory
* Measurement data are retained, even after a power interruption
* Saving of data sets on the CompactFlash card
* Instrument configuration through the keys or the setup program(CompactFlash card or interface)
* Evaluation of archived data with PC evaluation program
* Search function for history analysis
* Adaptation of the memory cycles to the specific process, using normal, time-of-day and event operation
* Freely configurable inputs
* Internal sampling rate 250msec for 3 or 6 analog inputs, minimum storage cycle 1sec
* Counters and integrators (6 channels)
* Math and logic module (6 channels)
* Integrated web server


Paperless recorder for capturing, visualizing, storing and evaluating measurement data, bezel size 144 x 200mm (70.6550/95.5010)
* No chart /pens
* Presentation of the measurement data in vertical/horizontal diagrams, bargraph, numerical
* Expanded batch reporting
* Local availability of the measurement data stored in RAM
* Database can be saved to a formatted 3.5" diskette
* Configuration of the instrument via keys, diskette or setup program
* Evaluation of the archived data through the PC evaluation program
* Conversion of the measurement data into spreadsheet formats
* Search function for history analysis
* Adaptation of the storage cycles to the individual process through: normal operation, event operation, daytime operation
* Report with minimum/maximum/average values and integrator
* Freely programmable inputs for resistance thermometers, thermocouples, d.c. current and d.c. voltage
* Sampling rate minimum 125msec with 12 analog inputs
* PROFIBUS-DP and Ethernet connection


Paperless recorder with CompactFlash card as storage medium, bezel size 200 x 144mm (70.6570)
* No chart /pens
* Presentation of the measurement data in vertical/horizontal diagrams, bar graph, numerical, ...
* Batch documentation
* Local availability of the measurement data stored in RAM
* Data records can be saved to a CompactFlash memory card
* Instrument can be configured from the keys, via the CompactFlash memory card or serial interface
* Evaluation of the archived data through the PC evaluation software
* Adaptation of the storage cycles to the individual process through normal operation, event operation, day-time operation
* Report with minimum/maximum/average values and integrator
* Freely programmable inputs for resistance thermometers, thermocouples, DC current and DC voltage
* Sampling cycle minimum 125msec with 12 analog inputs
* PROFIBUS-DP and Ethernet connection


Paperless recorder for capturing, visualizing, storing and evaluating measurement data, bezel size 144 x 144mm (70.6500/95.5015)
* Representation of measurement data in vertical diagrams (with scaling, numerical display or bargraph)
* Representation of event traces, such as "logic inputs"
* Local availability of the measurement data stored in the FLASH memory
* Measurement data are retained even after a power failure
* Data storage on a formatted 3.5" diskette
* Instrument configuration from the keys or via the setup program (diskette or serial interface)
* Evaluation of archived data through PC evaluation program
* Conversion of measurement data into spreadsheet formats
* Search function for history analysis
* Adaptation of the storage cycles to the individual process through normal, event and daytime operation
* Freely programmable inputs
* Internal sampling rate 250msec with 3 or 6 analog inputs; minimum storage cycle 1sec
* Counters and integrators
* Math and logic module


Paperless Recorder for acquisition of FDA-compliant measurement data with CompactFlash memory card, bezel size 200 x 144mm (70.6560)
* Conforms to FDA CFR Part 11
* Monitored back-panel cover
* No chart /pens
* Presentation of the measurement data in vertical/horizontal diagrams, bar graph, numerical
* Batch reporting
* Local availability of the measurement data stored in RAM
* Data records can be saved to a CompactFlash memory card
* Instrument can be configured from the keypad, via the CompactFlash memory card or serial interface
* Evaluation of the archived data through the PC evaluation software
* Adaptation of the storage cycles to the individual process through normal operation, event operation and day-time operation
* Report with minimum/maximum/ average values and integrator
* Freely programmable inputs for resistance thermometers, thermocouples, DC current and DC voltage
* Sampling cycle minimum 125msec with 12 analog inputs
* PROFIBUS-DP and Ethernet connection
* Integrated web server


Consumabile




ADAPTOARE DE SEMNAL DE TEMPERATURA

Analog 2-wire transmitter with digital adjustment (70.7030)
These transmitters are designed for industrial applications and are used to measure the temperature through Pt100 resistance thermometers in 2-/3-wire circuit connections (Pt1000 linearization on request).
The 0 - 10 V output signal is linear with temperature. The continuous analog signal path enables an extremely fast reaction time of the output to a change in temperature (continuous analog measurement instead of digital sampling rate), resulting in a low-noise output signal that is insensitive to interference.
A very high degree of precision - even with small ranges - is ensured thanks to the range-specific gain adjustment. Digital communication allows the transmitter to be adapted to the measurement task (range, probe break and fine calibration).


Programmable 2-wire transmitter (70.7010/95.6550), JUMO dTRANS T01 Ex Programmable 2-wire transmitter (70.7015/95.6555)
* As Ex version CE0032 II 1 G EEx ia IIC T6/T5/T4
* Input and output electrically isolated
* Freely configurable ranges
* Customized linearization for resistance thermometer and thermocouple
* Configuration via Windows setup program


Programmable 2-wire transmitter (70.7012/95.6552), JUMO dTRANS T01T HART® Programmable 2-wire transmitter (70.7013/95.6553)
* In rail-mounting housing
* Input and output electrically isolated
* Freely configurable ranges
* Customized linearization for resistance thermometer and thermocouple
* Configuation via Windows setup program
* Version dTRANS T01T HART® with HART®-interface


Analog 2-wire transmitter with digital adjustment (70.7033)
These transmitters are designed for industrial applications and are used to measure the temperature through Pt100 resistance thermometers in 2-/3-wire circuit connections (Pt1000 linearization on request).
The 0 - 10 V output signal is linear with temperature. The continuous analog signal path enables an extremely fast reaction time of the output to a change in temperature (continuous analog measurement instead of digital sampling rate), resulting in a low-noise output signal that is insensitive to interference.
A very high degree of precision - even with small ranges - is ensured thanks to the range-specific gain adjustment. Digital communication allows the transmitter to be adapted to the measurement task (range, probe break and fine calibration).


Programmable 4-wire transmitter (70.7021/95.6521)
The JUMO dTRANS T02 PCP transmitter incorporate a microprocessor for digital signal processing.
Input and output are electrically isolated. It can be mounted on a DIN rail, the electrical connection is by screw terminals for stranded or solid wire up to 2.5mm² conductor cross-section. The 0/4 - 20mA or 0/2 - 10V output signal is available either linearized (linear with temperature) or inverted (option). The transmitter can be programmed via the PC setup program, which is supplied as an accessory.
Additionally it is possible to program the limits of the limit comparators, and the frequency output. Current and voltage outputs are available directly on terminals. No hardware alterations are required.


Programmable 4-wire transmitter (70.7025/95.6525)
The JUMO dTRANS T02 Ex transmitter incorporate a microprocessor for digital signal processing.
Input and output are electrically isolated. It can be mounted on a DIN rail, the electrical connection is by screw terminals for stranded or solid wire up to 2.5mm² conductor cross-section. The 0/4 - 20mA or 0/2 - 10V output signal is available either linearized (linear with temperature) or inverted (option).
The transmitter can be programmed via the PC setup program, which is supplied as an accessory. Current and voltage outputs are available directly on terminals. No hardware alterations are required.


Analog 2-wire transmitter with digital adjustment for mounting on rail (70.7032)
These transmitters are designed for industrial applications and are used to measure the temperature through Pt100 resistance thermometers in 2-/3-wire circuit connections (Pt1000 linearization on request).
The 4 - 20 mA output signal is linear with temperature. The continuous analog signal path enables an extremely fast reaction time of the output to a change in temperature (continuous analog measurement instead of digital sampling rate), resulting in a low-noise output signal that is insensitive to interference.
A very high degree of precision - even with small ranges - is ensured thanks to the range-specific gain adjustment. Digital communication allows the transmitter to be adapted to the measurement task (range, probe break and fine calibration).


Four-wire Transmitter, settable via DIP switch/PC setup program (70.7040)
* Measuring range selectable via DIP switch or through the PC setup program
* Choice of signal output: 0 - 10V, 0 - 20mA or 4 - 20mA
* Fast response, thanks to continuous analog measurement
* Low-noise current signal, immune to interference
* Electrical isolation between input, output / mains supply
* Current/voltage output


Programmable 2-wire transmitter (70.7011/95.6551), JUMO dTRANS T01 HART®/Ex Programmable 2-wire transmitter (70.7016/95.6556)
* with HART® interface
* Type dTRANS T01 HART®/Ex with HART® interface and as Ex version: CE0032 Ex II 1 G EEx ia IIC T6/T5/T4; CE0032 Ex II 2 G EEx ia IIC T6/T5/T4
* input and output electrically isolated
* freely configurable ranges
* customized linearization for resistance thermometer and thermocouple
* configuration via Windows setup program


Analog 2-wire transmitter with digital adjustment (70.7031)
These transmitters are designed for industrial applications and are used to measure the temperature through Pt100 resistance thermometers in 2-/3-wire circuit connections (Pt1000 linearization on request).
The 4 - 20 mA output signal is linear with temperature. The continuous analog signal path enables an extremely fast reaction time of the output to a change in temperature (continuous analog measurement instead of digital sampling rate), resulting in a low-noise output signal that is insensitive to interference.
A very high degree of precision - even with small ranges - is ensured thanks to the range-specific gain adjustment. Digital communication allows the transmitter to be adapted to the measurement task (range, probe break and fine calibration).


Programmable 4-wire transmitter (70.7020/95.6520)
The JUMO dTRANS T02 junior transmitter incorporate a microprocessor for digital signal processing.
Input and output are electrically isolated. It can be mounted on a DIN rail, the electrical connection is by screw terminals for stranded or solid wire up to 2.5mm² conductor cross-section. The 0/4 - 20mA or 0/2 - 10V output signal is available either linearized (linear with temperature) or inverted (option).
The transmitter can be programmed via the PC setup program, which is supplied as an accessory. Current and voltage outputs are available directly on terminals. No hardware alterations are required.


LCD Programmable 4-wire transmitter (70.7022/95.6522)
The JUMO dTRANS T02 LCD transmitter incorporate a microprocessor for digital signal processing.
Input and output are electrically isolated. It can be mounted on a DIN rail, the electrical connection is by screw terminals for stranded or solid wire up to 2.5mm² conductor cross-section. The type, the 0/4 - 20mA or 0/2 - 10V output signal is available either linearized (linear with temperature) or inverted (option).
The transmitter can be programmed via the PC setup program, which is supplied as an accessory.
Additionally it is possible to program the limits of the limit comparators, and the frequency output. Current and voltage outputs are available directly on terminals. No hardware alterations are required.




SURSE DE ALIMENTARE, APLIFICATOARE, SEPARATOARE GALVANICE

Supply units for transmitters (70.7500/95.6024)
The supply units are used for the stabilised supply of transmitters. They provide a 24 V DC supply which is electrically isolated from the mains supply.


Isolating amplifier and supply isolator (70.7510/95.6055)
* Power supply for 2-wire transmitters and for isolating standard signals
* Protection of connected electronic equipment from impermissibly high working voltages
* Provision of floating output signals
* Avoidance of ground loops
* Conversion of standard signals, e. g. 0 - 10V input to 4 - 20mA output


Supply unit for transmitters (70.7520/95.6056)
* Ex version Ex II (1) G D [EEx ia] IIC oder [EEx ia] IIB, Ex II (2) G D [EEx ib IIC oder ] [EEx ib] IIB
* Supply unit to provide power for 2-wire transmitters, electrically isolated


Safety barriers to European Standard EN 50 014 and EN 50 020 (70.7590/95.2810)
Safety barriers are passive networks for separating intrinsically safe circuits from non-intrinsically safe ones without galvanic isolation.
Through the use of safety barriers it is possible to employ standard instrumentation and installation methods in the non-intrinsically safe parts of the circuit provided there are no voltage higher than 250 V during operation.
The safety barriers are designed in accordance with the European Standards EN 50 014 and EN 50 020 developed by CENELG.
The intrinsically safe output circuits of the safety barriers are suitable for hazardous atmospheres Group IIB and IIC within Category ia (Zone 1).




CONTACTOARE STATICE CU TIRISTORI

Thyristor power switches without heat sink (70.9010)
* Load currents 25A and 50A (max.)
* Load voltages 265V and 530V (max.)
* Control voltage 4 - 32V DC
* UL approval


Thyristor power switch with heat sink and semiconductor fuse for DIN-rail mounting or screw fixing (70.9025)
* Operates on the full-wave switching principle
* Load currents 25A / 50 A
* Logic control input 0-1 / 3.5-35V AC/DC
* Detects partial load fail
* Detects semiconductor fuse fail
* Fault detection e.g. on thyristor short-circuit
* LED for status of the control input
* LED for supply to control section electronics
* LED for partial load fail
* LED for semiconductor fuse fail
* LED signal on fault in the SCR module (silicon controlled rectifier)
* Two single-phase units can be wired up as an economy circuit for purely resistive loads


Power converter with amplitude control (70.9050)
* Protective operation when power supply operated under high resistive loads(flicker)
* Operation of low voltage heaters directly at the power supply without impedance-matching transformer
* Minimum harmonics in the instrument power supply and low weight (power transformer n/a)
* Short-circuit control when switching on
* Line current in proportion to the required power (amplitude control)
* Control independent of the heaters' resistive characteristics
* Minimum reactive power
* Compact dimensions
* The subordinate control action U2, P, I2 can be freely chosen
* Ageing process compensation for SIC heating elements
* Indicator showing when ageing can no longer be compensated by the voltage reserve1
* Resistance limitation, protection of Molybdenum Disilicide heating elements against overheating in the upper temperature range1
* Integrated semiconductor fuses to protect the IPC in the event of an earth short1


Thyristor power switches with integrated heat sink for DIN rail or screw mounting (70.9020)
* Load currents 3x20A, 30A and 45A (max.)
* Load voltages 265V and 660V (max.)
* Control voltage 4 - 32V DC
* UL approval


Thyristor unit for analogue control (70.9040)
* input for voltage, current and potentiometer
* input signal can be freely selected
* freely selectable operating mode (phase-angle/burst-firing operation)
* adjustable cut-back of first half-wave in burst-firing operation
* supply voltage monitoring
* input signal attenuation
* soft start in phase-angle operation
* U2 control with adjustable process value output
* master-slave economy circuit
* firing-pulse inhibit
* recognition of part-load failure for economy circuit




SOFTWARE SI ACCESORII

Software and Accessories (70.9700/95.9700)
Software and Accessories for Indicators, Recorders and Temperature transmitters


Software and Accessories (70.9770)
Software and Accessories for Programmers, Thermostats, Microstats and Controllers


Accessories for flush-panel mounting instruments to DIN (70.9710)
Protection cover AK-96
The protection cover AK-96 is available for protection against mechanical damage and unintentional or unauthorised manipulation, as well as protecting against dust and splashing water.
Special features
* lockable (plastic lock)
* high-impact clear plastic (polycarbonate)
* heat-resistant up to 130°C
* suitable for for flush-panel mounting instruments with 96 mm x 96 mm bezel(DIN 43 700)
* Protection rating IP 65
Protection cover AK-48/f
The protection cover is designed for controllers with nominal size of 48 mm x 48 mm.
The flexible cover protects against dust and splashing water while still allowing continued operation
Special features
* flexible clear plastic (soft PVC)
* nominal size 48 mm x 48 mm
* Protection rating IP 65




Copyright 2011 © Messystech srl
Gama foarte larga de produse in domeniul tehnicii de masurare si reglare, consultanta de specialitate, service in garantie si postgarantie.
Produsele noastre se aplica intr-o gama variata de domenii: industria energetica, industria chimica, industria alimentara, industria farmaceutica.
Aparate masura si control, manometre, traductoare, termometre, termostate, filtre, reductoare, inregistratoare, instrumente de afisare, presostate, termocuple, regulatoare,
vane, valve, robinete, senzori si aparate de masurare a temperaturii si umiditatii, regulatoare si tehnica de sistem, regulatoare in doua si trei puncte, programatoare,
circuite de masurare electrochimice, stabilizatoare de presiune comutatoare de presiune si comutatoare de presiune diferentiala, manometre in carcasa de otel si otel inox.